OJTECH — OUJI Industrial Technology

ISO 286 REFERENCE TABLE · SHAFT

f9 tolerance chart: ISO 286 shaft limits by size

Static f9 deviations and shaft limits at the upper-bound nominal of every ISO 286 size band from 1 to 500 mm.

This page answers a class-specific f9 tolerance chart query. The ISO 286 fits calculator remains the tool for arbitrary nominal sizes, paired hole/shaft callouts, measured values, and shareable calculations.

13 ISO 286 SIZE BANDS

f9 shaft limits by representative nominal size

Each representative nominal is the upper boundary of its displayed size band. Deviations and IT width are shown in micrometres; the resulting minimum and maximum are shown in millimetres.
f9 ISO 286 shaft deviations and limits for 13 nominal-size bands
Size band (mm)Representative nominal (mm)Upper deviation (µm)Lower deviation (µm)IT9 width (µm)Minimum / maximum (mm)
[1, 3]3−6−31252.969 / 2.994
(3, 6]6−10−40305.960 / 5.990
(6, 10]10−13−49369.951 / 9.987
(10, 18]18−16−594317.941 / 17.984
(18, 30]30−20−725229.928 / 29.980
(30, 50]50−25−876249.913 / 49.975
(50, 80]80−30−1047479.896 / 79.970
(80, 120]120−36−12387119.877 / 119.964
(120, 180]180−43−143100179.857 / 179.957
(180, 250]250−50−165115249.835 / 249.950
(250, 315]315−56−186130314.814 / 314.944
(315, 400]400−62−202140399.798 / 399.938
(400, 500]500−68−223155499.777 / 499.932

The IT9 tolerance width is constant within each displayed size band. Values shown are calculated at the representative upper-bound nominal. Some letter zones use finer fundamental-deviation sub-bands, so deviations may vary within a displayed band; use the calculator for the exact nominal.

Within a band where the deviations are unchanged, the micrometre deviations stay fixed while the absolute millimetre limits move with the selected nominal size.

DRAWING EXAMPLES

Common f9 callouts

f9 keeps the f shaft zone below nominal while using the broader IT9 tolerance width. Examples you can check across different size bands include:
25 MM WORKED CALLOUT25 f9 → 24.928 / 24.980 mm
Upper deviation
−20 µm
Lower deviation
−72 µm
IT9 width
52 µm
Load this shaft state in the calculator

READ THE CLASS CORRECTLY

f9: shaft zone f, IT grade 9

f

Shaft tolerance zone

Lowercase letters identify shaft tolerance zones.

9

IT tolerance grade

The grade selects the published tolerance width for each nominal-size band.

µm → mm

Deviation to absolute limit

Each deviation is added to the exact nominal diameter after conversion from micrometres to millimetres.

This static table is an engineering reference, not a replacement for a controlled drawing or licensed ISO 286 standard. Confirm standard edition, feature function, geometry, surface finish, and inspection method.

Return to the ISO 286 fits & tolerance calculator